13 CONVENTIONAL MODE OPERATION
The radio functions in the conventional mode when using conventional communications channels (non-
trunked). Each channel consists of a preset frequency pair for transmit and receive during repeater
operation or a single frequency for both transmit and receive during talk-around (no repeater) operation. To
use this mode, the operator selects a conventional system that includes one or more conventional channels.
Each conventional channel may have one or more features, such as Channel Guard, programmed when the
channel is selected.
The c button unmutes the receiver so activity on the selected channel can be monitored. When pressed
and held for approximately 3 seconds this button toggles conventional channel decoding (Channel Guard,
Digital Channel Guard or T99) ON and OFF, if programmed for the selected channel.
13.1 RECEIVING A CALL
1. Turn the radio on by rotating the POWER ON-OFF/VOLUME knob clockwise (out of detent).
A short alert signal (if enabled through programming) indicates the radio is ready to use.
2. Adjust the POWER ON-OFF/VOLUME knob to the desired volume level.
3. Select the desired conventional system and channel. The display indicates the current
conventional system and channel names.
4. The radio is now ready to receive calls.
5. When the radio receives a call (and the correct encoding is decoded, if programmed and enabled),
it unmutes on the channel and the BSY indicator comes on.
13.2 SENDING A CALL
1. Turn ON the radio and set the POWER ON-OFF/VOLUME knob to the desired volume level.
Select the desired conventional system and channel.
2. Ensure that the channel is not busy by pressing the c button to briefly disable any channel
decoding and unmute the receiver or observe the unlit BSY indicator. If the Channel Busy
Lockout feature is programmed for the selected channel, the radio will not transmit when the
channel is busy.
3. Press and hold the PTT button. The TX indicator will turn on and a short beep sounds (if
programmed) indicating that communication can begin.
4. Hold the microphone approximately three inches from the mouth and speak in a normal voice.
5. Release the PTT button when the transmission is complete and listen for a reply.
13.3 EMERGENCY OPERATION
If enabled, G-STAR emergency signaling can be transmitted when operating in the conventional mode.
This G-STAR signaling will transmit 5 times with a delay between each transmission. To send an
emergency call on the selected conventional system and channel (or on an optionally pre-programmed
conventional emergency system and channel), proceed as follows:
Press and hold the red E or “
E” button for approximately one second (this time is programmable and,
therefore, could be longer or shorter; check with the system administrator). The radio turns on the TX
indicator and proceeds to transmit the pre-programmed G-STAR emergency signaling sequence.
G-STAR is programmed to transmit in one of the following methods:
Zobrazit stránku 51
1 2 ... 47 48 49 50 51 52 53 54 55 56 57 ... 79 80

Komentáře k této Příručce

Žádné komentáře

Rockwell Automation 1771-IN ac (24V) Input Module Installation Instruc manuals

Owner’s manuals and user’s guides for Equipment Rockwell Automation 1771-IN ac (24V) Input Module Installation Instruc.
We providing 1 pdf manuals Rockwell Automation 1771-IN ac (24V) Input Module Installation Instruc for download free by document types: User Manual






More products and manuals for Equipment Rockwell Automation

Models Document Type
1771-IGD TTL Input Module Installation Instruction User Manual   Rockwell Automation 1771-IGD TTL Input Module Installation Instructions User Manual, 12 pages
Logix5000 Controllers Ladder Diagram Programming M User Manual   Rockwell Automation Logix5000 Controllers Ladder Diagram Programming Manual User Manual, 22 pages
1785-Lx0C15 ControlNet PLC-5 Programmable Controll User Manual   Rockwell Automation 1785-Lx0C15 ControlNet PLC-5 Programmable Controllers User Manual User Manual, 148 pages
1771-ID16 SERIES B Install Instr ac/dc (120V)Isola User Manual   Rockwell Automation 1771-ID16 SERIES B Install Instr ac/dc (120V)Isolated Input User Manual, 16 pages
1792D-16BVTOD ArmorBlock MaXum 16 Input Module Ser User Manual   Rockwell Automation 1792D-16BVTOD ArmorBlock MaXum 16 Input Module Series B User Manual, 16 pages
1757-FIM ProcessLogix Fieldbus Interface Module (F User Manual   Rockwell Automation 1757-FIM ProcessLogix Fieldbus Interface Module (FIM) Installation Instructions User Manual, 12 pages
1734-EPAC POINT I/O ac Power Supply User Manual   Rockwell Automation 1734-EPAC POINT I/O ac Power Supply User Manual, 16 pages
1738-OA2M12AC3 ArmorPoint AC Output Module, Series User Manual   Rockwell Automation 1738-OA2M12AC3 ArmorPoint AC Output Module, Series A User Manual, 12 pages
1794 FLEX I/O System with ControlLogix for SIL2 User Manual   Rockwell Automation 1794 FLEX I/O System with ControlLogix for SIL2 User Manual, 60 pages
1762-OB32T MicroLogix Solid State 24V DC Source Ou User Manual   Rockwell Automation 1762-OB32T MicroLogix Solid State 24V DC Source Output User Manual, 20 pages
1788-ENBT EtherNet/IP Daughtercard Installation In User Manual   Rockwell Automation 1788-ENBT EtherNet/IP Daughtercard Installation Instructions User Manual, 12 pages
1734-OW2_OW4, Series C Point I/O 2 and 4 Relay Out User Manual   Rockwell Automation 1734-OW2_OW4, Series C Point I/O 2 and 4 Relay Output Modules User Manual, 24 pages
1738-IE4CM12 ArmorPoint 4-Channel 24V dc Analog In User Manual   Rockwell Automation 1738-IE4CM12 ArmorPoint 4-Channel 24V dc Analog Input Modules, Series A User Manual, 16 pages
1756-HIST2G FactoryTalk Historian ME 2.1 Installat User Manual   Rockwell Automation 1756-HIST2G FactoryTalk Historian ME 2.1 Installation Instructions User Manual, 26 pages
1738-SSIM23 ArmorPoint I/O SSI Absolute Encoder Mo User Manual   Rockwell Automation 1738-SSIM23 ArmorPoint I/O SSI Absolute Encoder Module, Series A User Manual, 14 pages
1756-IH16ISOE ControlLogix Sequence of Events Modu User Manual   Rockwell Automation 1756-IH16ISOE ControlLogix Sequence of Events Module User Manual, 160 pages
1783-US8T Stratix 2000 Ethernet Unmanaged Switch I User Manual   Rockwell Automation 1783-US8T Stratix 2000 Ethernet Unmanaged Switch Installation Instructions User Manual, 16 pages
1746-NI8 SLC 500 Analog Input Module Instructions User Manual   Rockwell Automation 1746-NI8 SLC 500 Analog Input Module Instructions User Manual, 20 pages
1753-L28BBB-M_P GuardPLC 1600 Controllers User Manual   Rockwell Automation 1753-L28BBB-M_P GuardPLC 1600 Controllers User Manual, 20 pages
1756-Mxxxx ControlLogix SERCOS interface Module In User Manual   Rockwell Automation 1756-Mxxxx ControlLogix SERCOS interface Module Installation Instructions User Manual, 20 pages